Online transformer based UPS TS33

Dalton TS33 Online Double Conversion UPS Three Phase 3:3
Output galvanic isolation transformer
10kVA – 200kVA

  The output isolation transformer provides high reliability to adapt 
  different harsh industrial environments and protects the critical loads 
  100% 3-phase unbalance load adapt different kinds of complex applications.
  Dual air ducts design offer good cooling to protect components and extend 
  the service life Dual power supply redundancy. 
  Wide input voltage range provides high adaptability to the grid and extend 
  main PCB board with professional electromagnetic shielding improve
  reliable performance of EMC.
– True galvanic isolation transformer design
– Small Footprint
– High Efficiency 94%
– All Series Touch Screen Design
– DSP technology guarantees high reliability
– Dual input supplies 

Specifications

Model TS3320
20K
TS3330
30K
TS3340
40K
TS3360
60K
TS3380
80K
TS33100
100K
TS33120
120K
TS33160
160K
TS33200
200K
Rating Power 20KVA
16KW
30KVA
24KW
40KVA
32KW
60KVA
48KW
80KVA
64KW
100KVA
80KW
120KVA
96KW
160KVA
128KW
200KVA
160KW
Input Input system 3 Phases + N & earth ground
Voltage range 380/400/415}25%
Power factor ≥0.99
Frequency 50/60}10%5% optional
Output Output system 3 Phases + N & earth ground
Rated voltage L-N:220/230/240}1%, L-L:380/400/415}1%,
Power factor 0.8
Voltage precision ±2%
Voltage distortion THD≤2% (linear load)
Output waveform Pure Sinewave
Output frequency 50/60}0.2 (battery mode)
Inverter overload capacity
(Utility power, 25Co)
125% load for 10mins, 150% load for 1 min
Transfer time 0ms
Crest factor 3:1
DISPLAY/ INTERFACE LCD Display LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
LED Status Indicator Utility power; Battery discharge; Inverter On
External Communication MODBUS/RS485 and dry contact (RS232 and SNMP adapter are optional)
Display Touch screen + LED
Communication software Windows XP/ 2003 and later version; Linux; Unix
Optional SNMP Card/ Dry Contact AS400 Card/ CMC Card/ RS485 Card/ EMD Monitoring Device
Battery Batteries voltage 348 (360 setting) 384(348/360/372 setting)
Battery Type Sealed maintenance-free lead –acid battery / Gel Battery / NiCd
Backup Time (25Co) Full load ≥ 5min (Standard)
Battery quantity 32 32 (29,30,31)
General Temperature 0 ~ 40℃
Humidity 0 ~ 95%, No condensation
Altitude <1000m
Efficiency Line: ≥ 94%
Alarm Overload, abnormal AC input, low battery, UPS failure
Noise (dB) <40 < 55  - 60     
Protection Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
L*W*H (mm) 656×405×817 821x432x1159 975×554×1286 1050×705×1646
Weight (kg) 145 195 280 365 475 580 650 740            -         800