Dalton UPS C500 PLUS Series​​

C500 PLUS Single phase smart online UPS 

Pure sinewave
1KVA – 10kVA

The C500 PLUS Professional uninterruptible power supply
range uses state-of-the-art technology and components
to provide highest network protection where the load 
is continuously supplied by the inverter with real filtered 
and stabilized waveform and frequency to the highest standards.
C500 PLUS is ideally suited for mission critical loads such as vital servers
,network and telecommunication equipment.
  • Online UPS Design 1 PF.
  • Pure Sine Wave.
  • Transformer less UPS Technology.
  • Optional SNMP Communication Port.
  • Cold Start Function.

Specifications

Model
    C500       PLUS
1K
C500 PLUS   1KS
C500 PLUS
2K
C500  PLUS
    2KS
C500 PLUS
3K
C500 PLUS
3KS
C500
PLUS
6K
C500
PLUS 
6KS
C500
 PLUS 
10K
C500
PLUS
10KS
Rating 1KVA/1KW 2KVA/2KW 3KVA/3KW 6KVA/6KW 10KVA/10KW
Input Input system Single phase & earth ground
Voltage range (90±5)VAC~ (300±5)VAC (120±5)VAC~ (274±5)VAC
Power factor ≥0.99
Voltage range of bypass (80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC Could be adjusted by software) (60±5)VAC~ (300±5)VAC (default: 80VAC~264VAC Could be adjusted by software)
Output Output system Single phase & earth ground
Rated voltage 200V/208V/220V/230V/240V
Power factor 1
Voltage precision ±2% ±1%
Voltage distortion ≤ 3% at linear load ≤ 2% at linear load
Output waveform Pure Sine Wave
Output frequency Normal mode 1.The output frequency synchronizes with the input frequency when the input frequency is in the range of 46Hz~ 54Hz.
Battery mode
2.The output frequency is 50Hz when the input frequency is not in the range of 46Hz~ 54Hz.
3.Can be set as 60Hz.
Efficiency 93% >97%
Inverter overload capacity

(Utility power, 25CO)
100% ± 5% < Load ≤ 105% ± 5% Overload warning only

105% ± 5% < Load < 125% ± 5% 10s transfer to bypass

Load > 125% ± 5%, 300ms transfer to bypass
Transfer time 0ms (Normal mode←→ Battery mode)
<4ms (Normal mode←→Bypass mode)
Crest factor 3:1
DISPLAY/ INTERFACE LCD Display AC/ DC voltages; kVA/ kW; Frequency; Temperature; Battery & load level
LED Status Indicator Utility power; Battery discharge; Inverter On
External Communication RS232 / RJ11 / Optional Intelligent Slot
Control 3 control push button for POWER ON / POWER OFF / FUNCTION KEY
Communication software Windows XP/ 2003 and later version; Linux; Unix
Optional SNMP Card/ USB Card/ Dry Contact AS400 Card/ CMC Card/ RS485 Card/ EMD Monitoring Device
Battery Batteries voltage 36VDC 48VDC 72VDC 192VDC 192VDC 192VDC 192VDC
Battery Type Sealed maintenance-free lead –acid battery
Backup Time (25CO) Full load ≥ 5min (Standard)
Battery quantity 3 None 6 None 6 None 16 None 16 None
Charge current 1A 6A 1A 8A 1A 8A 1A 12A 1A 12A
L*W*H (mm) 350×144×230 425×190×328 425×190×328 533x260x560 425x190x328 533x260x560 533x260x501
Weight (kg) 11.5 6 22.5 10 27.5 11 55 12.5 62 21