Dalton Ups R10 Series

True online double conversion rack mounted UPS 1KVA – 10kVA
Dalton R10 is a unique range of high density UPS systems
that can be installed whether on the floor in tower form or
in rack mount cabinet configurations powering a wide range
of applications.
The R10 is an ultra efficient system resulting in improved operational
performance up to 98% in ECO mode, 94% in inverter mode ,
providing a much greener product with smaller battery and longer
autonomy backup times.
Rack/Tower convertible design.
True Double conversion ONLINE technology.
Filtered, and stabilized pure sine wave supply.
Advanced battery discharge management.
High efficiency reducing energy costs.
Extendable runtime.
Specifications
Model | R101000K 1K |
R101000KS 1KS |
R102000K 2K |
R102000KS 2KS |
R103000K 3K |
R103000KS 3KS |
R106000K 6K |
R106000KS 6KS |
R1010000K 10K |
R1010000KS 10KS |
||
Rating Power | 1KVA / 1000W | 2KVA / 2000W | 3KVA / 3000W | 6KVA / 6000W | 10kKA / 10000W | |||||||
Input | Input system | Single phase & earth ground | ||||||||||
Voltage range | (90±5)VAC~ (300±5)VAC | (120±5)VAC~ (274±5)VAC | ||||||||||
Power factor | ≥0.99 | |||||||||||
Voltage range of bypass | (80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC Could be adjusted by software) | (60±5)VAC~ (300±5)VAC (default: 80VAC~264VAC Could be adjusted by software) | ||||||||||
Output | Output system | Single phase & earth ground | ||||||||||
Rated voltage | 200V/208V/220V/230V/240V | |||||||||||
Power factor | 1 | |||||||||||
Voltage precision | ±1% | ±1% |
||||||||||
Voltage distortion | ≤ 3% at linear load | ≤ 2% at linear load | ||||||||||
Output waveform | Pure Sinewave | |||||||||||
Output frequency | Normal mode | 1.The output frequency synchronizes with the input frequency when the input frequency is in the range of 46Hz~ 54Hz. | ||||||||||
Battery mode | 2.The output frequency is 50Hz when the input frequency is not in the range of 46Hz~ 54Hz. 3.Can be set as 60Hz. |
|||||||||||
Efficiency | 86% | >940% | ||||||||||
Inverter overload capacity (Utility power, 25CO) |
105% ± 5% < Load ≤ 125% ± 5% 50s transfer to bypass 125% ± 5% < Load < 150% ± 5% 25s transfer to bypass Load > 150% ± 5%, 300ms transfer to bypass |
|||||||||||
Transfer time | 0ms (Normal mode←→ Battery mode) | |||||||||||
<4ms (Normal mode←→Bypass mode) | ||||||||||||
Crest factor | 3:1 | |||||||||||
DISPLAY/ INTERFACE | LCD Display | AC/ DC voltages; kVA/ kW; Frequency; Temperature; Battery & load level | ||||||||||
LED Status Indicator | Utility power; Battery discharge; Inverter On | |||||||||||
External Communication | RS232 / RJ11 / Optional Intelligent Slot | |||||||||||
Control | 3 control push button for POWER ON / POWER OFF / FUNCTION KEY | |||||||||||
Communication software | Windows XP/ 2003 and later version; Linux; Unix | |||||||||||
Optional | SNMP Card/ USB Card/ Dry Contact AS400 Card/ CMC Card/ RS485 Card/ EMD Monitoring Device | |||||||||||
Battery | Batteries voltage | 36VDC | 72VDC | 96VDC | 192VDC | 192VDC | 192VDC | 192VDC | ||||
Battery Type | Sealed maintenance-free lead –acid battery | |||||||||||
Backup Time (25CO) | Full load ≥ 5min (Standard) | |||||||||||
Battery quantity | 2 | None | 4 | None | 6 | None | 16 | None | 16 | None | ||
Charge current | 1A | 6.5A | 1A | 5.5A | 1A | 5.5A | 1A | 5.5A | 1A | 5.5A | ||
L*W*H (mm) | 482×746×88 | 482×650×132 | 482×650×132 | 482×650×132 | 482×650×132 | 482×650×132 | 482×650×132 | |||||
Weight (kg) | 16 | 10 | 25 | 10 | 30 | 10 | 55 | 20 | 62 | 21 |