DALTON UPS C500 SERIES

Dalton Ups C500 Series True Online Double Conversion UP

                                    1kVA – 10kVA

The Dalton UPS C500 Series can be installed with internal

batteries as standard. 

This removes the need for external battery cabinets on 

standard run times, enabling you to maximize valuable floor space.

 Additional flexibility is achieved for the Dalton UPS C500 Series

 through its sophisticated design. The selectable input between
 Single phase and three phases allow users to retain electrical

 infrastructure and save costs where applicable.

– Online double conversion topology
– High efficiency up to 94%
– Intelligent monitoring software
– EPO connection
– Wide input voltage window

Specifications

Model C500
1KVA
C500
2KVA
C500
3KVA
C500
6KVA
C500
10KVA
Rating Power
 1KVA/900W
  2KVA/1800W 3KVA/2700W 6KVA/5400W 10KVA/9000W
Input Input system Single Phase 
Voltage range                       176-276VAC (100% load), 120-276VAC (50% load)
Power factor ≥0.99
Frequency 50/60Hz
Output Output system Single Phase
Rated voltage 208*/220/230VAC
Power factor 0.9
Voltage precision ±2%
Voltage distortion
< 3% THDV on non-linear load
                 Output                    wave form                                                                                                                  Pure  Sinewave
Output frequency 50/60Hz (±10%)
Inverter overload
capacity
(Utility power,25©)
100-105%: no alarm
105-125% : load transfers to Bypass mode after 10 minutes
125-150% : load transfers to Bypass mode after 30s
Transfer time 0ms
Crest factor 3:1
DISPLAY/ INTERFACE LCD Display LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
         LED Status          Indicator  Utility power; Battery discharge; Inverter On
External             Communication USB/RS485 and  (RS232 and SNMP adapter are optional)
PARALLEL 4 Units
Communication
software
Windows XP/ 2003 and later version; Linux; Unix
Optional EX SNMP / dry contact relays / Modbus
Battery Batteries voltage 24VDC 48VDC 72/96VDC 192/240VDC
Battery Type Sealed maintenance-free lead –acid battery
Backup Time
(25℃)
Full load ≥ 5min (Standard)
Battery quantity 2 4 6/8 16/20
General Temperature 0 ~ 40℃
Humidity <95% (non-condensing)
Altitude <1000m
Efficiency >90% (Line mode), >92% (Battery mode), >96% (Eco mode)
FUNCTIONS  Expandable Battery Modules, LCD
Noise (dB) <35dB
Protection Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
L*W*H (mm) 290 x 100 x 140 345 x 140 x 170 380 x 125 x 225 400 x 170 x 250
Weight (kg) 5 9 10 14 20