DALTON UPS b33 (80-200kva) SERIES

B33 Plus Smart Online Double Conversion UPS
Three Phase 3:3 Dalton B33 Plus
80KVA – 200KVA
The On-Line- B33 Series is an uninterruptible power supply incorporating
double-converter technology. IT , Medical provides perfect protection specifically for strict load.
The double-converter principle eliminates all mains power disturbances.
In the event of power failure, the maintenance-free batteries power the inverter.
Designed with high protections
UPS offers the greatest degree of availability in power protection and provides
continuous high-quality AC power to connect strict load
-Online true double conversion ups
-Output Short Circuit and Overload Protection
– Cold Start Function
– Optional SNMP Communication Port
– Maintenance Bypass Switch
Specifications
Model |
B33L80000
|
B33L100000
|
B33L120000
|
B33L150000
|
B33L160000
|
B33L180000
|
B33L200000
|
Rating Power |
80 KVA
80 KW
|
100 KVA
100 KW
|
120 KVA
120 KW
|
150 KVA
150 KW
|
160 KVA
160 KW
|
180 KVA
180 KW
|
200 KVA
200 KW
|
INPUT | |||||||
Rated voltage
|
380 V / 400 V / 415 VAC | ||||||
Voltage range
|
346 V ~ 456 V ( full load )
304 V ~ 346 V ( Voltage rating 10% ) |
||||||
Rated frequency
|
50 / 60 Hz | ||||||
Frequency range
|
50 / 60 Hz ± 5 Hz | ||||||
Power factor
|
≥ 0.99 | ||||||
Total harmonic distortion (THDI)
|
≤ 3%
|
||||||
Input current-limiting
|
1.1 times of rated current ( 0.1 ~ 1.1 settable ) | ||||||
Rectifier delay start
|
10 s (1 ~ 300 settable ) | ||||||
Bypass voltage range
|
± 20% (settable) | ||||||
OUTPUT | |||||||
Rated voltage
|
380 V / 400 V / 415 VAC | ||||||
Voltage regulation
|
± 1% | ||||||
Frequency
|
Synchronized with utility in mains mode; 50 / 60 Hz ± 0.1% in battery mode | ||||||
Waveform
|
Pure sinewave | ||||||
Crest factor
|
3:1 | ||||||
Total harmonic distortion (THDV)
|
≤ 2% ( Resistive load); ≤ 5% (non-linear load ) | ||||||
Transfer time
|
0 ms | ||||||
Inverter overload capability
|
Load ≤ 105%,long time work: 105% < load ≤ 110%,transfer to bypass in 60 min 110% < load ≤ 125%, transfer to bypass in 10 min 125% < load ≤ 150%, transfer to bypass in 1 min 150% < load ≤ 200%, transfer to bypass in 200 ms 200% < load, inverter off (UPS shutdown) in 100 ms and transfer to bypass output |
||||||
Slight adjustment of inverter
output voltage |
± 5 V | ||||||
BATTERIES | |||||||
DC voltage
|
( 80KVA To 200KVA 384VDC ) | ||||||
Number of battery
|
( 80KVA To 200KVA As Installed ) | ||||||
Charging current | Charging rate (settable) × battery capacity (settable) × number of battery group (settable) | ||||||
Battery state display
|
Battery remaining capacity and backup time | ||||||
Battery self test
|
Settable periodic self-test; manually configurable test time and voltage | ||||||
SYSTEM | |||||||
Efficiency
|
Line mode ≥ 96%, ECO mode ≥ 98% | ||||||
Max. parallel numbers
|
4
|
||||||
Protections
|
Short-circuit, overload, over temperature, over voltage, under voltage, battery low voltage and fan failure | ||||||
Communications
|
RS232 / RS485 / dry contacts (standard), SNMP (optional) | ||||||
IP rating
|
IP 20 | ||||||
Display
|
4.3 inches LCD touch screen ( Optional ) | ||||||
OTHERS | |||||||
Operating temperature
|
0 ~ 40℃ | ||||||
Storage temperature
|
- 25℃ ~ 55℃ ( without battery ) | ||||||
Humidity
|
0 ~ 95% ( non-condensing ) | ||||||
Noise level at 1 m
|
< 50 dB | < 65dB | |||||
Dimensions (W×L×H) (mm)
|
472×910×1260 | 585×910×1115 | 900×600×1600 | ||||
weight (kg) | 110 | 154 | 180 | 236 | 254 | 265 | 302 |


Model |
B33L80000
|
B33L100000
|
B33L120000
|
B33L150000
|
B33L160000
|
B33L180000
|
B33L200000
|
Rating Power |
80 KVA
80 KW
|
100 KVA
100 KW
|
120 KVA
120 KW
|
150 KVA
150 KW
|
160 KVA
160 KW
|
180 KVA
180 KW
|
200 KVA
200 KW
|
INPUT | |||||||
Rated voltage
|
380 V / 400 V / 415 VAC | ||||||
Voltage range
|
346 V ~ 456 V ( full load )
304 V ~ 346 V ( Voltage rating 10% ) |
||||||
Rated frequency
|
50 / 60 Hz | ||||||
Frequency range
|
50 / 60 Hz ± 5 Hz | ||||||
Power factor
|
≥ 0.99 | ||||||
Total harmonic distortion (THDI)
|
≤ 3%
|
||||||
Input current-limiting
|
1.1 times of rated current ( 0.1 ~ 1.1 settable ) | ||||||
Rectifier delay start
|
10 s (1 ~ 300 settable ) | ||||||
Bypass voltage range
|
± 20% (settable) | ||||||
OUTPUT | |||||||
Rated voltage
|
380 V / 400 V / 415 VAC | ||||||
Voltage regulation
|
± 1% | ||||||
Frequency
|
Synchronized with utility in mains mode; 50 / 60 Hz ± 0.1% in battery mode | ||||||
Waveform
|
Pure sinewave | ||||||
Crest factor
|
3:1 | ||||||
Total harmonic distortion (THDV)
|
≤ 2% ( Resistive load); ≤ 5% (non-linear load ) | ||||||
Transfer time
|
0 ms | ||||||
Inverter overload capability
|
Load ≤ 105%,long time work: 105% < load ≤ 110%,transfer to bypass in 60 min 110% < load ≤ 125%, transfer to bypass in 10 min 125% < load ≤ 150%, transfer to bypass in 1 min 150% < load ≤ 200%, transfer to bypass in 200 ms 200% < load, inverter off (UPS shutdown) in 100 ms and transfer to bypass output |
||||||
Slight adjustment of inverter
output voltage |
± 5 V | ||||||
BATTERIES | |||||||
DC voltage
|
( 80KVA To 200KVA 384VDC ) | ||||||
Number of battery
|
( 80KVA To 200KVA As Installed ) | ||||||
Charging current | Charging rate (settable) × battery capacity (settable) × number of battery group (settable) | ||||||
Battery state display
|
Battery remaining capacity and backup time | ||||||
Battery self test
|
Settable periodic self-test; manually configurable test time and voltage | ||||||
SYSTEM | |||||||
Efficiency
|
Line mode ≥ 96%, ECO mode ≥ 98% | ||||||
Max. parallel numbers
|
4
|
||||||
Protections
|
Short-circuit, overload, over temperature, over voltage, under voltage, battery low voltage and fan failure | ||||||
Communications
|
RS232 / RS485 / dry contacts (standard), SNMP (optional) | ||||||
IP rating
|
IP 20 | ||||||
Display
|
4.3 inches LCD touch screen ( Optional ) | ||||||
OTHERS | |||||||
Operating temperature
|
0 ~ 40℃ | ||||||
Storage temperature
|
- 25℃ ~ 55℃ ( without battery ) | ||||||
Humidity
|
0 ~ 95% ( non-condensing ) | ||||||
Noise level at 1 m
|
< 50 dB | < 65dB | |||||
Dimensions (W×L×H) (mm)
|
472×910×1260 | 585×910×1115 | 900×600×1600 | ||||
weight (kg) | 110 | 154 | 180 | 236 | 254 | 265 | 302 |