Dalton UPS C500 PLUS Series
C500 PLUS Single phase smart online UPS
Pure sinewave
1KVA – 10kVA
The C500 PLUS Professional uninterruptible power supply
range uses state-of-the-art technology and components
to provide highest network protection where the load
is continuously supplied by the inverter with real filtered
and stabilized waveform and frequency to the highest standards.
C500 PLUS is ideally suited for mission critical loads such as vital servers
,network and telecommunication equipment.
- Online UPS Design 1 PF.
- Pure Sine Wave.
- Transformer less UPS Technology.
- Optional SNMP Communication Port.
- Cold Start Function.
Specifications
Model |
C500 PLUS
1K |
C500 PLUS 1KS |
C500 PLUS 2K |
C500 PLUS
2KS |
C500 PLUS 3K |
C500 PLUS
3KS
|
C500
PLUS
6K |
C500
PLUS
6KS |
C500
PLUS
10K |
C500
PLUS
10KS |
||
Rating | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW | 6KVA/6KW | 10KVA/10KW | |||||||
Input | Input system | Single phase & earth ground | ||||||||||
Voltage range | (90±5)VAC~ (300±5)VAC | (120±5)VAC~ (274±5)VAC | ||||||||||
Power factor | ≥0.99 | |||||||||||
Voltage range of bypass | (80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC Could be adjusted by software) | (60±5)VAC~ (300±5)VAC (default: 80VAC~264VAC Could be adjusted by software) | ||||||||||
Output | Output system | Single phase & earth ground | ||||||||||
Rated voltage | 200V/208V/220V/230V/240V | |||||||||||
Power factor | 1 | |||||||||||
Voltage precision | ±2% | ±1% | ||||||||||
Voltage distortion | ≤ 3% at linear load | ≤ 2% at linear load | ||||||||||
Output waveform | Pure Sine Wave | |||||||||||
Output frequency | Normal mode | 1.The output frequency synchronizes with the input frequency when the input frequency is in the range of 46Hz~ 54Hz. | ||||||||||
Battery mode |
2.The output frequency is 50Hz when the input frequency is not in the range of 46Hz~ 54Hz.
3.Can be set as 60Hz.
|
|||||||||||
Efficiency | 93% | >97% | ||||||||||
Inverter overload capacity
(Utility power, 25CO)
|
100% ± 5% < Load ≤ 105% ± 5% Overload warning only 105% ± 5% < Load < 125% ± 5% 10s transfer to bypass Load > 125% ± 5%, 300ms transfer to bypass |
|||||||||||
Transfer time | 0ms (Normal mode←→ Battery mode) | |||||||||||
<4ms (Normal mode←→Bypass mode) | ||||||||||||
Crest factor | 3:1 | |||||||||||
DISPLAY/ INTERFACE | LCD Display | AC/ DC voltages; kVA/ kW; Frequency; Temperature; Battery & load level | ||||||||||
LED Status Indicator | Utility power; Battery discharge; Inverter On | |||||||||||
External Communication | RS232 / RJ11 / Optional Intelligent Slot | |||||||||||
Control | 3 control push button for POWER ON / POWER OFF / FUNCTION KEY | |||||||||||
Communication software | Windows XP/ 2003 and later version; Linux; Unix | |||||||||||
Optional | SNMP Card/ USB Card/ Dry Contact AS400 Card/ CMC Card/ RS485 Card/ EMD Monitoring Device | |||||||||||
Battery | Batteries voltage | 36VDC | 48VDC | 72VDC | 192VDC | 192VDC | 192VDC | 192VDC | ||||
Battery Type | Sealed maintenance-free lead –acid battery | |||||||||||
Backup Time (25CO) | Full load ≥ 5min (Standard) | |||||||||||
Battery quantity | 3 | None | 6 | None | 6 | None | 16 | None | 16 | None | ||
Charge current | 1A | 6A | 1A | 8A | 1A | 8A | 1A | 12A | 1A | 12A | ||
L*W*H (mm) | 350×144×230 | 425×190×328 | 425×190×328 | 533x260x560 | 425x190x328 | 533x260x560 | 533x260x501 | |||||
Weight (kg) | 11.5 | 6 | 22.5 | 10 | 27.5 | 11 | 55 | 12.5 | 62 | 21 |