Dalton Ups R10 Series

True online double conversion rack mounted UPS                                                                                                          1KVA – 10kVA

Dalton R10 is a unique range of high density UPS systems 

that can be installed whether on the floor in tower form or

in rack mount cabinet configurations powering a wide range 

of applications.

The R10 is an ultra efficient system resulting in improved operational 

performance up to 98% in ECO mode, 94% in inverter mode , 

providing a much greener product with smaller battery and longer

 autonomy backup times. 

  • Rack/Tower convertible design.
  • True Double conversion ONLINE technology.
  • Filtered, and stabilized pure sine wave supply.
  • Advanced battery discharge management.
  • High efficiency reducing energy costs.
  • Extendable runtime. 

Specifications

Model R101000K
1K
R101000KS
1KS
R102000K 
2K
R102000KS 
2KS
R103000K
3K
R103000KS
3KS
R106000K
6K
R106000KS
6KS
R1010000K
10K
R1010000KS
10KS
Rating Power 1KVA / 1000W 2KVA / 2000W 3KVA / 3000W 6KVA / 6000W 10kKA / 10000W
Input Input system Single phase & earth ground
Voltage range (90±5)VAC~ (300±5)VAC (120±5)VAC~ (274±5)VAC
Power factor ≥0.99
Voltage range of bypass (80±5)VAC~ (286±5)VAC (default: 80VAC~264VAC Could be adjusted by software) (60±5)VAC~ (300±5)VAC (default: 80VAC~264VAC Could be adjusted by software)
Output Output system Single phase & earth ground
Rated voltage 200V/208V/220V/230V/240V
Power factor 1
Voltage precision ±1% ±1%
Voltage distortion ≤ 3% at linear load ≤ 2% at linear load
Output waveform Pure Sinewave
Output frequency Normal mode 1.The output frequency synchronizes with the input frequency when the input frequency is in the range of 46Hz~ 54Hz.
Battery mode 2.The output frequency is 50Hz when the input frequency is not in the range of 46Hz~ 54Hz.

3.Can be set as 60Hz.
Efficiency 86% >940%
Inverter overload capacity

(Utility power, 25CO)
105% ± 5% < Load ≤ 125% ± 5% 50s transfer to bypass
125% ± 5% < Load < 150% ± 5% 25s transfer to bypass
Load > 150% ± 5%, 300ms transfer to bypass
Transfer time 0ms (Normal mode←→ Battery mode)
<4ms (Normal mode←→Bypass mode)
Crest factor 3:1
DISPLAY/ INTERFACE LCD Display AC/ DC voltages; kVA/ kW; Frequency; Temperature; Battery & load level
LED Status Indicator Utility power; Battery discharge; Inverter On
External Communication RS232 / RJ11 / Optional Intelligent Slot
Control 3 control push button for POWER ON / POWER OFF / FUNCTION KEY
Communication software Windows XP/ 2003 and later version; Linux; Unix
Optional SNMP Card/ USB Card/ Dry Contact AS400 Card/ CMC Card/ RS485 Card/ EMD Monitoring Device
Battery Batteries voltage 36VDC 72VDC 96VDC 192VDC 192VDC 192VDC 192VDC
Battery Type Sealed maintenance-free lead –acid battery
Backup Time (25CO) Full load ≥ 5min (Standard)
Battery quantity 2 None 4 None 6 None 16 None 16 None
Charge current 1A 6.5A 1A 5.5A 1A 5.5A 1A 5.5A 1A 5.5A
L*W*H (mm) 482×746×88 482×650×132 482×650×132 482×650×132 482×650×132 482×650×132 482×650×132
Weight (kg) 16 10 25 10 30 10 55 20 62 21