Online transformer based UPS TS33 Plus

Dalton TS33 Plus Online Double Conversion UPS Three Phase 3:3
With Isolation Transformer
10kVA – 200kVA

  The output isolation transformer provides high reliability to adapt 
  different harsh industrial environments and protects the critical 
  loads 100% 3-phase unbalance load adapt to different kinds of applications.  
  Dual power supply redundancy.
  Wide input voltage range provides high adaptability to the grid and 
  extend the battery service life Main PCB board with professional 
  electromagnetic shielding improve reliable performance of EMC    
  Dual air ducts design offer good cooling to protect the
  components and extend the service life.
– True galvanic isolation transformer  design
– Output power factor 1.0
– Small Footprint
– High Efficiency 95%
– All Series Touch Screen Design
– DSP technology guarantees high   reliability

Specifications

Model
TS3320
Plus 
20K
TS3330
Plus 
30K
TS3340
Plus 
40K
TS3360
Plus 
60K
TS3380
Plus 
80K
TS33100
Plus 
100K
TS33120
Plus 
120K
TS33160
Plus 
160K
TS33200
Plus 
200K
Rating Power 20KVA
18KW
30KVA
27KW
40KVA
36KW
60KVA
54KW
80KVA
72KW
100KVA
90KW
120KVA
108KW
160KVA
144KW
200KVA
180KW
Input Input system 3 Phases + N & earth ground
Voltage range 380/400/415}25%
Power factor ≥0.99
Frequency 50/60}10%5% optional
Output Output system 3 Phases + N & earth ground
Rated voltage L-N:220/230/240}1%, L-L:380/400/415}1%,
Power factor 0.9
Voltage precision ±2%
Voltage distortion THD≤2% (linear load)
Output waveform Pure Sinewave
Output frequency 50/60}0.2 (battery mode)
Inverter overload capacity
(Utility power, 25Co)
125% load for 10mins, 150% load for 1 min
Transfer time 0ms
Crest factor 3:1
DISPLAY/ INTERFACE LCD Display LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
LED Status Indicator Utility power; Battery discharge; Inverter On
External Communication MODBUS/RS485 and dry contact (RS232 and SNMP adapter are optional)
Display Touch screen + LED
Communication software Windows XP/ 2003 and later version; Linux; Unix
Optional SNMP Card/ Dry Contact AS400 Card/ CMC Card/ RS485 Card/ EMD Monitoring Device
Battery Batteries voltage 348 (360 setting) 384(348/360/372 setting)
Battery Type Sealed maintenance-free lead –acid battery / Gel Battery / NiCd
Backup Time (25Co) Full load ≥ 5min (Standard)
Battery quantity 32 32 (29,30,31)
General Temperature 0 ~ 40℃
Humidity 0 ~ 95%, No condensation
Altitude <1000m
Efficiency Line: ≥ 95%
Alarm Overload, abnormal AC input, low battery, UPS failure
Noise (dB) <55 < 60  - 65         
Protection Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
L*W*H (mm) 656×405×817 821x432x1159 975×554×1286 1050×705×1646
Weight (kg) 145 195 280 365 475 580 650 740            -         800